Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
1.
Ophthalmology ; 131(3): 370-382, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38054909

RESUMO

PURPOSE: To determine the intraocular pressure (IOP) reduction of various trabecular procedures (a form of minimally invasive glaucoma surgery [MIGS]) combined with cataract surgery compared with cataract surgery alone, to compare the safety of the various trabecular procedures, and to highlight patient characteristics that may favor one trabecular procedure over another. METHODS: A search of English-language peer-reviewed literature in the PubMed database was initially conducted in February 2021 and updated in April 2023. This yielded 279 articles. Twenty studies met initial inclusion and exclusion criteria and were assessed for quality by the panel methodologist. Of these, 10 were rated level I, 3 were rated level II, and 7 were rated level III. Only the 10 level I randomized controlled trials (RCTs) were included in this assessment, and all were subject to potential industry-sponsorship bias. RESULTS: The current analysis focuses on the amount of IOP reduction (in studies that involved medication washout) and on IOP reduction with concurrent medication reduction (in studies that did not involve medication washout). Based on studies that performed a medication washout, adding a trabecular procedure to cataract surgery provided an additional 1.6 to 2.3 mmHg IOP reduction in subjects with hypertensive, mild to moderate open-angle glaucoma (OAG) at 2 years over cataract surgery alone, which itself provided approximately 5.4 to 7.6 mmHg IOP reduction. In other words, adding a trabecular procedure provided an additional 3.8% to 8.9% IOP reduction over cataract surgery alone, which itself provided 21% to 28% IOP reduction. There was no clear benefit of one trabecular procedure over another. Patient-specific considerations that can guide procedure selection include uveitis predisposition, bleeding risk, metal allergy, and narrowing of Schlemm's canal. There are no level I data on the efficacy of trabecular procedures in subjects with pretreatment IOP of 21 mmHg or less. CONCLUSIONS: Trabecular procedures combined with cataract surgery provide an additional mild IOP reduction over cataract surgery alone in hypertensive OAG subjects. Additional research should standardize outcome definitions, avoid industry sponsorship bias, and study the efficacy of these procedures in normotensive OAG. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.


Assuntos
Extração de Catarata , Catarata , Glaucoma de Ângulo Aberto , Glaucoma , Oftalmologia , Humanos , Glaucoma de Ângulo Aberto/complicações , Glaucoma de Ângulo Aberto/cirurgia
2.
Ophthalmology ; 131(1): 37-47, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37702635

RESUMO

PURPOSE: To review the current published literature for high-quality studies on the use of selective laser trabeculoplasty (SLT) for the treatment of glaucoma. This is an update of the Ophthalmic Technology Assessment titled, "Laser Trabeculoplasty for Open-Angle Glaucoma," published in November 2011. METHODS: Literature searches in the PubMed database in March 2020, September 2021, August 2022, and March 2023 yielded 110 articles. The abstracts of these articles were examined to include those written since November 2011 and to exclude reviews and non-English articles. The panel reviewed 47 articles in full text, and 30 were found to fit the inclusion criteria. The panel methodologist assigned a level I rating to 19 studies and a level II rating to 11 studies. RESULTS: Data in the level I studies support the long-term effectiveness of SLT as primary treatment or as a supplemental therapy to glaucoma medications for patients with open-angle glaucoma. Several level I studies also found that SLT and argon laser trabeculoplasty (ALT) are equivalent in terms of safety and long-term efficacy. Level I evidence indicates that perioperative corticosteroid and nonsteroidal anti-inflammatory drug eye drops do not hinder the intraocular pressure (IOP)-lowering effect of SLT treatment. The impact of these eye drops on lowering IOP differed in various studies. No level I or II studies exist that determine the ideal power settings for SLT. CONCLUSIONS: Based on level I evidence, SLT is an effective long-term option for the treatment of open-angle glaucoma and is equivalent to ALT. It can be used as either a primary intervention, a replacement for medication, or an additional therapy with glaucoma medications. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.


Assuntos
Glaucoma de Ângulo Aberto , Glaucoma , Oftalmologia , Trabeculectomia , Humanos , Glaucoma/cirurgia , Glaucoma de Ângulo Aberto/cirurgia , Lasers , Soluções Oftálmicas , Malha Trabecular/cirurgia , Estados Unidos
3.
Ophthalmology ; 131(2): 240-248, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38069944

RESUMO

PURPOSE: To evaluate the current published literature on the utility of the 10-2 visual field (VF) testing strategy for the evaluation and management of early glaucoma, defined here as mean deviation (MD) better than -6 decibels (dB). METHODS: A search of the peer-reviewed literature was last conducted in June 2023 in the PubMed database. Abstracts of 986 articles were examined to exclude reviews and non-English-language articles. After inclusion and exclusion criteria were applied, 26 articles were selected, and the panel methodologist rated them for strength of evidence. Thirteen articles were rated level I, and 8 articles were rated level II. The 5 level III articles were excluded. Data from the 21 included articles were abstracted and reviewed. RESULTS: The central 12 locations on the 24-2 VF test grid lie within the central 10 degrees covered by the 10-2 VF test. In early glaucoma, defects detected within the central 10 degrees generally agree between the 2 tests. Defects within the central 10 degrees of the 24-2 VF test can predict defects on the 10-2 VF test, although the 24-2 may miss defects detected on the 10-2 VF test. In addition, results from the 10-2 VF test show better association with findings from OCT scans of the macular ganglion cell complex. Modifications of the 24-2 test that include extra test locations within the central 10 degrees improve detection of central defects found on 10-2 VF testing. CONCLUSIONS: Evidence to date does not support routine testing using 10-2 VF for patients with early glaucoma. However, early 10-2 VF testing may provide sufficient additional information for some patients, particularly those with a repeatable defect within the central 12 locations of the standard 24-2 VF test or who have inner retinal layer thinning on OCT scans of the macula. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.


Assuntos
Glaucoma , Oftalmologia , Humanos , Estados Unidos , Campos Visuais , Escotoma/diagnóstico , Células Ganglionares da Retina , Tomografia de Coerência Óptica/métodos , Testes de Campo Visual , Glaucoma/diagnóstico , Glaucoma/complicações , Pressão Intraocular
4.
Ophthalmology ; 131(2): 227-239, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38069945

RESUMO

PURPOSE: To evaluate the recently published literature on the efficacy and safety of the use of aqueous shunts with extraocular reservoir for the management of adult open-angle glaucomas (OAGs). METHODS: A search of peer-reviewed literature was last conducted in April 2023 of the PubMed database and included only articles published since the last aqueous shunt Ophthalmic Technology Assessment, which assessed articles published before 2008. The abstracts of these 419 articles were examined, and 58 studies were selected for full-text analysis. After inclusion and exclusion criteria were applied, 28 articles were selected and assigned ratings by the panel methodologist according to the level of evidence. Twenty-five articles were rated level I and 3 articles were rated level II. There were no level III articles. RESULTS: Implantation of aqueous shunts with extraocular reservoir can lower intraocular pressure (IOP) by between one-third and one-half of baseline IOP, depending on whether it is undertaken as the primary or secondary glaucoma surgery. Success rates for aqueous shunts were found to be better than for trabeculectomies in eyes with prior incisional surgery. Conversely, in eyes without prior incisional surgery, implantation of aqueous shunts was found to have an overall lower success rate as the primary glaucoma procedure compared with trabeculectomy. Although both valved and nonvalved aqueous shunts with extraocular reservoir were effective, the nonvalved device generally achieved slightly lower long-term IOPs with fewer glaucoma medications and less need for additional glaucoma surgery. Both devices slow the rates of visual field progression with efficacy comparable with that of trabeculectomy. Early aqueous humor suppression after aqueous shunt implantation is recommended for the management of the postoperative hypertensive phase and long-term IOP control. No strong evidence supports the routine use of mitomycin C with aqueous shunt implantation for OAG. CONCLUSIONS: Implantation of aqueous shunts with extraocular reservoir, including valved or nonvalved devices, has been shown to be an effective strategy to lower IOP. Strong level I evidence supports the use of aqueous shunts with extraocular reservoir by clinicians for the management of adult OAG. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.


Assuntos
Implantes para Drenagem de Glaucoma , Glaucoma de Ângulo Aberto , Glaucoma , Oftalmologia , Trabeculectomia , Adulto , Humanos , Estados Unidos , Glaucoma/cirurgia , Glaucoma de Ângulo Aberto/cirurgia , Pressão Intraocular , Trabeculectomia/métodos , Resultado do Tratamento
5.
Ophthalmol Ther ; 12(6): 2863-2880, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37698824

RESUMO

Glaucoma is a leading cause of vision loss. First line therapy for primary open angle glaucoma (POAG) are topical ocular hypotensive drops. Patient adherence with topical therapy for glaucoma is a significant challenge with a reported adherence of 60%. The purpose of this review is to discuss factors associated with glaucoma adherence (including demographic factors, cost, patient education, health beliefs, treatment burden and regimen, and physical limitations) and to explore potential interventions to improve medication adherence. Articles included in this review were found by searching PubMed and Google Scholar using the key words "Glaucoma Treatment Adherence" and "Glaucoma Treatment Compliance." Data from this review demonstrates that higher medication cost, lower patient education/literacy levels, and being of African and Hispanic descent are associated with lower medication adherence rates. The data is inconclusive on whether medication regimen complexity lowers patient medication adherence rates. Interventions that have successfully improved medication adherence rates for minority patients have focused on building trust and addressing fears and false beliefs. For cost, explicit physician communication to patients regarding medication cost is important and can help the physician determine any patient concerns about cost. Outside the USA, adherence has been improved through adherence-contingent rebate systems and government subsidies. Most interventions that aim to increase adherence target patient education and literacy with the following interventions demonstrating efficacy: written instructions targeting glaucoma-specific health literacy, literacy level appropriate glaucoma education videos, and interactive and personalized educational programs. More clinic infrastructure and programs that utilize patient reminder tools and patient educators could help physicians and patients in support of these personalized action plans.

6.
Invest Ophthalmol Vis Sci ; 64(7): 4, 2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-37261385

RESUMO

Purpose: Assess how the roles of refractive error (RE) and ocular biometrics as risk factors for primary open-angle glaucoma (POAG) differ by race and ethnicity. Methods: Data from the Los Angeles Latino Eye Study (LALES) and the Chinese American Eye Study (CHES), two population-based epidemiological studies, were retrospectively analyzed. Multivariable logistic regression and interaction term analyses were performed to assess relationships between POAG and its risk factors, including RE and axial length (AL), and to assess effect modification by race/ethnicity. Results: Analysis included 7601 phakic participants of LALES (47.3%) and CHES (52.7%) with age ≥ 50 years. Mean age was 60.6 ± 8.3 years; 60.9% were female. The prevalence and unadjusted risk of POAG were higher in LALES than CHES (6.0% and 4.0%, respectively; odds ratio [OR] = 1.55; P < 0.001). In the multivariable analysis, significant risk factors for POAG included Latino ethnicity (OR = 2.25; P < 0.001), refractive myopia (OR = 1.54 for mild, OR = 2.47 for moderate, OR = 3.94 for high compared to non-myopes; P ≤ 0.003), and longer AL (OR = 1.37 per mm; P < 0.001). AL (standardized regression coefficient [SRC] = 0.3) was 2.7-fold more strongly associated with POAG than high myopia status (SRC = 0.11). There was no modifying effect by race/ethnicity on the association between RE (per diopter) or AL (per millimeter) and POAG (P = 0.49). Conclusions: Although the POAG risk conferred by myopic RE and longer AL is similar between Latino and Chinese Americans, the difference in POAG prevalence between the two groups is narrowed by higher myopia prevalence among Chinese Americans. Racial/ethnic populations with higher myopia incidence may become disproportionately affected by POAG in the context of the global myopia epidemic.


Assuntos
Glaucoma de Ângulo Aberto , Miopia , Erros de Refração , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Glaucoma de Ângulo Aberto/epidemiologia , Estudos Retrospectivos , Miopia/epidemiologia , Fatores de Risco , Biometria , Pressão Intraocular
7.
Br J Ophthalmol ; 107(6): 795-801, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-35063932

RESUMO

PURPOSE: To assess the optimal number and orientation of anterior segment optical coherence tomography (AS-OCT) images for accurately measuring ocular biometric parameters in angle closure eyes. METHODS: Subjects with angle closure, defined as >3 quadrants of non-visible pigmented trabecular meshwork on static gonioscopy, were selected from the Chinese American Eye Study. Mean angle opening distance (AOD500) was calculated using four images (0°-180°, 45°-225°, 90°-270° and 135°-315° meridians) from one eye per subject. Ten eyes from each quartile of AOD500 measurements were randomly selected for detailed 32-image analysis of 10 biometric parameters, including AOD500, iris curvature (IC), anterior chamber depth (ACD), lens vault (LV), and anterior chamber area (ACA). Mean and range of measurements from 1, 2, 4, 8 or 16 images were compared with 32-image values for all parameters. RESULTS: 40 out of 335 eyes with angle closure were selected for 32-image analysis. Deviation from the 32-image mean was between 0.44% and 19.31% with one image, decreasing to 0.08% to 4.21% with two images for all parameters. Deviation from the 32-image range of measurements was between 54.67% to 88.94% with one image, decreasing to <7.00% with eight images for all parameters except ACD and ACA. Orienting the first image analysed along the 25°-205° meridian better approximated the range of measurements when four or fewer images were analysed. CONCLUSIONS: Sectoral anatomical variations in angle closure eyes are easily misrepresented based on current AS-OCT imaging conventions. A revised multi-image approach can better capture the mean and range of biometric measurements.


Assuntos
Segmento Anterior do Olho , Glaucoma de Ângulo Fechado , Humanos , Segmento Anterior do Olho/diagnóstico por imagem , Biometria , População do Leste Asiático , Glaucoma de Ângulo Fechado/diagnóstico , Gonioscopia , Pressão Intraocular , Iris/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Malha Trabecular/diagnóstico por imagem , Asiático , China/etnologia
8.
Br J Ophthalmol ; 107(4): 540-546, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-34740885

RESUMO

PURPOSE: To determine the relationship of various systemic and ocular characteristics with perifoveal and macular vessel density in healthy African American eyes. DESIGN: A population-based cross-sectional study of prospectively recruited African Americans ≥40 years of age. Participants underwent 3×3 mm and 6×6 mm macula scans using spectral-domain optical coherence tomography angiography (OCTA), clinical examinations and clinical questionnaires. Participants with glaucoma, severe non-proliferative diabetic retinopathy, proliferative diabetic retinopathy and macular oedema were excluded. Custom MATLAB based software quantified vessel area density (VAD) and vessel skeleton density (VSD) in the superficial retinal layer of the macula. Multivariable regression analysis, controlling for inter-eye correlation, was performed to determine systemic and ocular determinants of macular vessel metrics using stepwise selection. Candidate variables included: age, gender, body mass index, history of smoking, history of diabetes, diabetes duration, history of stroke or brain haemorrhage, systolic blood pressure, diastolic blood pressure (DBP), pulse pressure, mean arterial pressure, central subfield thickness (CSFT), visual field mean deviation, intraocular pressure, axial length (AL), mean ocular perfusion pressure and signal strength (SS). RESULTS: A total of 2221 OCTA imaged eyes from 1472 participants were included in this study. Reduced perifoveal and macular VAD and VSD were independently associated with longer AL, reduced SS, reduced CSFT and older age. Male gender and lower DBP were also associated with reduced perifoveal and macular VSD. CONCLUSIONS: When interpreting OCTA images in a clinical setting, it is important to consider the effects ocular and systemic characteristics may have on the macular microcirculation.


Assuntos
Retinopatia Diabética , Vasos Retinianos , Humanos , Masculino , Negro ou Afro-Americano , Estudos Transversais , Retinopatia Diabética/diagnóstico , Angiofluoresceinografia/métodos , Pressão Intraocular , Tomografia de Coerência Óptica/métodos , Feminino , Adulto
9.
Ophthalmology ; 130(4): 433-442, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36529572

RESUMO

PURPOSE: To review the current published literature on the utility of corneal hysteresis (CH) to assist the clinician in the diagnosis of glaucoma or in the assessment of risk for disease progression in existing glaucoma patients. METHODS: Searches of the peer-reviewed literature in the PubMed database were performed through July 2022. The abstracts of 423 identified articles were examined to exclude reviews and non-English articles. After inclusion and exclusion criteria were applied, 19 articles were selected, and the panel methodologist rated them for level of evidence. Eight articles were rated level I, and 5 articles were rated level II. The 6 articles rated level III were excluded. RESULTS: Corneal hysteresis is lower in patients with primary open-angle glaucoma, primary angle-closure glaucoma, pseudoexfoliative glaucoma, and pseudoexfoliation syndrome compared with normal subjects. Interpretation of low CH in patients with high intraocular pressure (IOP) or on topical hypotensive medications is complicated by the influence of these parameters on CH measurements. However, CH is also lower in treatment-naïve, normal-tension glaucoma patients compared with normal subjects who have a similar IOP. In addition, lower CH is associated with an increased risk of progression of glaucoma based on visual fields or structural markers in open-angle glaucoma patients, including those with apparently well-controlled IOP. CONCLUSIONS: Corneal hysteresis is lower in glaucoma patients compared with normal subjects, and lower CH is associated with an increased risk of disease progression. However, a causal relationship remains to be demonstrated. Nevertheless, measurement of CH complements current structural and functional assessments in determining disease risk in glaucoma suspects and patients. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found after the references.


Assuntos
Glaucoma de Ângulo Aberto , Glaucoma , Oftalmologia , Humanos , Fenômenos Biomecânicos , Córnea/diagnóstico por imagem , Progressão da Doença , Elasticidade , Glaucoma/diagnóstico , Glaucoma de Ângulo Aberto/diagnóstico , Pressão Intraocular , Tonometria Ocular , Estados Unidos
10.
J Glaucoma ; 31(9): 773-782, 2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-35726955

RESUMO

PRCIS: Peripapillary vessel parameters from optical coherence tomography angiography (OCTA) 4.5×4.5 mm scans in nonglaucomatous and glaucomatous eyes showed high repeatability and reproducibility, with higher reliability for commercially developed OCTA parameters compared with custom OCTA parameters. PURPOSE: The purpose of this study was to assess intrasession repeatability versus intersession reproducibility of peripapillary vessel parameters from 4.5×4.5 mm OCTA scans in nonglaucomatous eyes and glaucomatous eyes. MATERIALS AND METHODS: In a longitudinal study, peripapillary OCTA scans were quantified using research-oriented custom quantification software that calculated vessel area density (VAD) and flux and clinic-oriented commercially developed software (Cirrus 11.0) that calculated perfusion density (PD) and flux index (FI). Intrasession repeatability and intersession reproducibility were evaluated using within-eye coefficient of variation (CV W ) and intraclass correlation coefficient (ICC). RESULTS: With 127 nonglaucomatous eyes, intrasession CV W for VAD, PD, flux, and FI were 1.900%, 1.174%, 2.787%, and 1.425%, respectively. The intersession CV W were 2.039%, 1.606%, 4.053%, and 2.798%, respectively. Intrasession ICC ranged from 0.903 to 0.956, and intersession ICC ranged from 0.850 to 0.896. Among 144 glaucomatous eyes, intrasession CV W for VAD, PD, flux, and FI were: 3.841%, 1.493%, 5.009%, and 2.432%, respectively. The intersession CV W were 4.991%, 2.155%, 6.360%, and 3.458%, respectively. Intrasession ICC ranged from 0.956 to 0.969, and intersession ICC ranged from 0.918 to 0.964. CONCLUSIONS: Among nonglaucomatous and glaucomatous eyes, the majority of peripapillary OCTA vessel parameters from 4.5×4.5 mm scans had greater intrasession repeatability than intersession reproducibility. There was a greater agreement for the commercially developed quantification parameters than for their custom quantification counterparts.


Assuntos
Glaucoma , Tomografia de Coerência Óptica , Angiofluoresceinografia/métodos , Glaucoma/diagnóstico , Humanos , Pressão Intraocular , Estudos Longitudinais , Reprodutibilidade dos Testes , Vasos Retinianos , Tomografia de Coerência Óptica/métodos
11.
Curr Eye Res ; 47(7): 1068-1076, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35385336

RESUMO

PURPOSE: Using optical coherence tomography angiography (OCTA), this study compared intrasession repeatability versus intersession reproducibility of macular vessel parameters in glaucoma and non-glaucoma subjects. METHODS: 6 × 6 mm2 macular OCTA scans (Cirrus HD-OCT 5000) were acquired from glaucomatous and non-glaucomatous subjects as part of an observational, longitudinal study. Vessel area density (VAD) and vessel skeleton density (VSD) were calculated using research-based quantification software while perfusion density (PDZ) and vessel density (VDZ) were calculated using commercially developed software (Cirrus 11.0, Carl Zeiss Meditec). Intrasession repeatability and intersession reproducibility were determined using within-eye standard deviation (SW), within-eye coefficient of repeatability (CRW), within-eye coefficient of variation (CVW), and intraclass correlation coefficients (ICC). RESULTS: The intrasession repeatability and intersession reproducibility for macular OCTA parameters were similar to one another for both non-glaucomatous and glaucomatous eyes. Intrasession CVW from the non-glaucoma group (n = 73) was 1.097% for VAD, 1.007% for VSD, 2.980% for PDZ, and 2.714% for VDZ. Intersession CVW from the non-glaucoma group (n = 55) was 1.389% for VAD, 1.279% for VSD, 2.935% for PDZ, and 2.695% for VDZ. Intrasession CVW from the glaucoma group (n = 59) was 1.189% for VAD, 0.970% for VSD, 3.827% for PDZ, and 3.542% for VDZ. Intersession CVW from the glaucoma group (n = 45) was 1.412% for VAD, 1.132% for VSD, 3.915% for PDZ, and 3.654% for VDZ. Non-glaucomatous intrasession ICC ranged from 0.711 to 0.824, non-glaucomatous intersession ICC ranged from 0.649 to 0.762, glaucomatous intrasession ICC ranged from 0.710 to 0.853, and glaucomatous intersession ICC ranged from 0.661 to 0.827. CONCLUSIONS: Macular OCTA scans can be a useful tool in monitoring the longitudinal progression of glaucoma due to their high repeatability and reproducibility.


Assuntos
Glaucoma , Tomografia de Coerência Óptica , Angiofluoresceinografia/métodos , Glaucoma/diagnóstico , Humanos , Estudos Longitudinais , Fibras Nervosas , Reprodutibilidade dos Testes , Tomografia de Coerência Óptica/métodos
12.
J Glaucoma ; 31(4): 242-249, 2022 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-35089892

RESUMO

PRCIS: Among subjects with glaucoma, wedge-shaped defects on optical coherence tomography angiography (OCTA) were associated with disc hemorrhages (DH), paracentral visual field (VF) defects, increased cup-to-disc ratio (CDR), and thinner retinal nerve fiber layer (RNFL). PURPOSE: To examine determinants of wedge defects on peripapillary OCTA in glaucoma. MATERIALS AND METHODS: A total of 278 eyes of 186 subjects with mild to severe primary open-angle glaucoma underwent 6×6 spectral-domain OCTA imaging of the superficial peripapillary retina from 2016 to 2020 at an academic practice. Wedge defects were defined as focal microvasculature loss that extends outward from the optic nerve in an arcuate, wedge shape. Logistic regression models controlling for intereye correlation identified variables significantly associated with wedge defects. Eyes with profound microvasculature loss in both hemispheres were excluded. Candidate variables included: age, sex, race or ethnicity, diabetes, hypertension, follow-up duration, baseline untreated intraocular pressure, intraocular pressure at time of imaging, DH history, paracentral VF defects, CDR, central corneal thickness, spherical equivalent, VF mean deviation, RNFL thickness, and glaucoma stage. RESULTS: Of 278 eyes, 126 (45.3%) had wedge defects in at least 1 hemisphere. In our multivariable logistic regression model, wedge defects were associated with DH history [odds ratio (OR): 3.19, 95% confidence interval (CI): 1.05-9.69, P=0.041], paracentral VF defects [OR: 4.38 (95% CI: 2.11-9.11), P<0.0001], larger CDR [OR: 1.27 (95% CI: 1.03-1.56), P=0.024, per 0.1 increase], and thinner RNFL [OR: 1.71 (95% CI: 1.25-2.34), P=0.0009, per 10 µm decrease]. CONCLUSION: DH history and paracentral VF defects were independently associated with wedge defects on OCTA, which was present in 45.3% of primary open-angle glaucoma patients. These findings may provide insight into glaucoma pathogenesis.


Assuntos
Glaucoma de Ângulo Aberto , Disco Óptico , Angiografia , Glaucoma de Ângulo Aberto/complicações , Humanos , Pressão Intraocular , Fibras Nervosas/patologia , Disco Óptico/patologia , Prevalência , Retina , Tomografia de Coerência Óptica , Campos Visuais
13.
Am J Ophthalmol ; 237: 183-192, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34736951

RESUMO

PURPOSE: To assess ocular biometric determinants of dark-to-light change in anterior chamber angle width and identify dynamic risk factors in primary angle closure disease (PACD). DESIGN: Population-based cross-sectional study. METHODS: Chinese American Eye Study (CHES) participants underwent anterior segment optical coherence tomography imaging in the dark and light. Static dark and light biometric parameters, including angle opening distance, 750 µm (AOD750), anterior chamber width (ACW), lens vault (LV), and pupillary diameter (PD) were measured, and dynamic dark-to-light changes were calculated. Contributions by static and dynamic parameters to dark-to-light changes in AOD750 were assessed using multivariable linear regression models with standardized regression coefficients (SRCs) and semipartial correlation coefficients squared (SPCC2). PACD was defined as ≥3 quadrants of gonioscopic angle closure. RESULTS: The analysis included 1011 participants. All biometric parameters differed between dark and light (P < .05). On multivariable regression analysis, change in ACW (SRC = -0.35, SPCC2 = 0.081) and PD (SRC = -0.46, SPCC2 = 0.072) were the strongest determinants of dark-to-light change in AOD750 (overall R2 = 0.40). Dark-to-light increase in AOD750 was less in eyes with than without PACD (0.081 mm and 0.111 mm, respectively; P < .001). ACW increased in eyes with PACD and decreased in eyes without PACD from dark to light (P < .025), whereas change in PD was similar (P = .28). CONCLUSIONS: Beneficial angle widening effects of transitioning from dark to light are attenuated in eyes with PACD, which appears related to aberrant dark-to-light change in ACW. These findings highlight the importance of assessing the angle in both dark and light to identify potential dynamic mechanisms of angle closure.


Assuntos
Glaucoma de Ângulo Fechado , Segmento Anterior do Olho/diagnóstico por imagem , Asiático , Estudos Transversais , Glaucoma de Ângulo Fechado/diagnóstico , Gonioscopia , Humanos , Pressão Intraocular , Tomografia de Coerência Óptica/métodos
14.
Invest Ophthalmol Vis Sci ; 62(9): 37, 2021 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-34311470

RESUMO

Purpose: The purpose of this study was to investigate how axial length (AL) changes the relationship of intraocular pressure (IOP) with peripapillary vessel density (pVD) in glaucoma versus non-glaucomatous eyes. Methods: A population-based, cross-sectional study of 2127 African Americans aged 40 years and older in Inglewood, California, were imaged with 6 × 6-mm optic disc optical coherence tomography angiography scans. There were 1028 healthy subjects (1539 eyes) and 65 subjects with glaucoma (86 eyes) who met inclusion criteria. A multivariable linear mixed effects regression model investigated the relationship of IOP on pVD after controlling for signal strength, retinal nerve fiber layer thickness, and age. These results were stratified by AL groups. Results: Higher IOP was a significant predictor of lower pVD among subjects with glaucoma (P = 0.009), but not among healthy subjects (P = 0.26). After stratifying by the sample median AL (23.46 mm), higher IOP was associated with lower pVD among subjects with glaucoma with longer AL (≥ 23.46 mm, P = 0.005), but not among those in the shorter AL (< 23.46 mm, P = 0.45). IOP was not significantly associated with pVD among healthy subjects in either AL stratum. Conclusions: Among subjects with glaucoma with longer AL, IOP was significantly associated with pVD. This relationship was not seen among subjects with glaucoma with shorter AL or non-glaucomatous subjects in either AL group. These findings support the hypothesis that disturbed retinal autoregulation may be present in subjects with glaucoma with longer AL. Longitudinal studies are needed to further investigate whether axial elongation increases glaucoma risk by compromising retinal autoregulation.


Assuntos
Comprimento Axial do Olho/diagnóstico por imagem , Negro ou Afro-Americano , Glaucoma/fisiopatologia , Pressão Intraocular/fisiologia , Densidade Microvascular/fisiologia , Disco Óptico/diagnóstico por imagem , Vasos Retinianos/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , California/epidemiologia , Estudos Transversais , Feminino , Glaucoma/diagnóstico , Glaucoma/etnologia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Índice de Gravidade de Doença , Tomografia de Coerência Óptica/métodos
15.
Am J Ophthalmol ; 230: 156-165, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34102157

RESUMO

PURPOSE: To investigate hemiretinal asymmetry in radial peripapillary capillary vessel area density (VAD) of healthy, glaucoma suspect, and glaucoma eyes of varying severity and its diagnostic utility for glaucoma. DESIGN: Population-based, cross-sectional study. METHODS: Optic disc scans (6 × 6 mm) were collected on optical coherence tomography angiography (OCTA) to obtain VAD and on optical coherence tomography (OCT) to measure circumpapillary retinal nerve fiber layer (RNFL) thickness. Hemiretinal difference in VAD (hdVAD) was defined as the absolute difference between superior and inferior hemiretinal VAD. Age-adjusted multivariable linear regression of hdVAD on glaucoma severity was performed. Areas under curves (AUCs) were calculated from predicted probabilities generated by multiple logistic regression of glaucoma severity on age-adjusted single and combined parameters. RESULTS: A total of 1,043 eyes of 1,043 participants (587 healthy, 270 suspect, 67 mild, 54 moderate, 65 severe glaucoma) were included. After age adjustment, mean hdVAD was similar between healthy and suspect (P = .225), higher in mild vs suspect (P < .001), and higher in moderate vs mild (P = .018), but lower in severe vs moderate (P = .001). AUCs of hdVAD were highest for discriminating mild (0.685) and moderate (0.681) glaucoma from healthy. Combining hdVAD and global RNFL (gRNFL) yielded the highest AUCs of all parameters for mild (0.818) and any POAG (0.859) and resulted in significantly better diagnostic accuracy than either hdVAD or gRNFL alone (P < .05 for all comparisons). CONCLUSIONS: hdVAD is higher in early glaucoma and may help with early detection when damage is focal, but its diagnostic ability appears less robust in advanced glaucoma when damage is diffuse.


Assuntos
Glaucoma de Ângulo Aberto , Glaucoma , Estudos Transversais , Glaucoma/diagnóstico , Humanos , Pressão Intraocular , Fibras Nervosas , Células Ganglionares da Retina , Vasos Retinianos/diagnóstico por imagem , Tomografia de Coerência Óptica , Campos Visuais
16.
J Glaucoma ; 30(8): 666-671, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-33979111

RESUMO

PRECIS: An association between macular vessel density (VD) and total retinal blood flow (TRBF) was demonstrated in subjects with primary open-angle glaucoma (POAG) and visual field (VF) loss. PURPOSE: The purpose of this study was to report relationships of macular VD metrics and TRBF in POAG. MATERIALS AND METHODS: A total of 24 POAG and 19 healthy control subjects participated in the study. Subjects underwent optical coherence tomography and angiography for measurements of inner retinal thickness (IRT), VD, and spacing between large vessels (SLV) and small vessels (SSV). Doppler optical coherence tomography imaging was performed for TRBF measurement. In POAG subjects, automated perimetry was performed and VF loss expressed as mean deviation was measured. RESULTS: Compared with the control group, POAG group had decreased VD, TRBF, IRT, and increased SLV (P<0.0001). Decreased VD (Pearson correlation, r=0.51; P<0.0001; N=43) and increased SLV (Spearman correlation, rs=-0.47; P=0.001) were correlated with decreased TRBF. Decreased VD and SSV (r≥0.39; P≤0.001; N=43) and increased SLV (rs=-0.71; P<0.0001) were associated with decreased IRT. Decreased VF mean deviation was correlated with decreased VD, SSV, IRT (r≥0.53; P≤0.001; N=24), and with increased SLV (rs=-0.84; P<0.0001). CONCLUSIONS: The finding of an association between macular VD and TRBF supports the role of vascular factors in the pathophysiology of POAG and potential conduct of future studies aimed at identifying multiple image-based vascular metrics for disease diagnosis.


Assuntos
Glaucoma de Ângulo Aberto , Estudos Transversais , Glaucoma de Ângulo Aberto/diagnóstico , Humanos , Pressão Intraocular , Fibras Nervosas , Vasos Retinianos/diagnóstico por imagem , Tomografia de Coerência Óptica , Campos Visuais
17.
Am J Ophthalmol ; 231: 58-69, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34051173

RESUMO

PURPOSE: To compare dynamic ranges and steps to measurement floors of peripapillary and macular metrics from a complex signal-based optical microangiography (OMAGC) optical coherence tomography angiography (OCTA) device for glaucoma with those of OCT measurements. DESIGN: Cross-sectional study. METHODS: Imaging of 252 eyes from 173 patients with glaucoma and 123 eyes from 92 subjects without glaucoma from a glaucoma clinic was quantified using custom and commercial software. Metrics from OCT (retinal nerve fiber layer [RNFL], ganglion cell/inner plexiform layer [GCIPL]) and OCTA (custom: peripapillary vessel area density [pVAD], macular vessel area density [mVAD], and macular vessel skeleton density [mVSD]; commercial: peripapillary perfusion density [pPDZ], macular perfusion density [mPDZ], and macular vessel density [mVDZ]) were plotted against visual field mean deviation (MD) with linear change-point analyses, measurement floors, and steps to floors. RESULTS: Mean MD (dB) for glaucomatous eyes was -5.77 (-6.45 to -5.10). The number of eyes with mild glaucoma (MD >-6), moderate glaucoma (MD -6 to -12), and severe glaucoma (MD <-12) were 164, 50, and 38, respectively. pPDZ yielded the lowest estimated floor at -26.6 dB (standard error [SE] 1.53), followed by OCTA macular metrics (-25 to -21 dB; SE 1.03) and pVAD (-17.6 dB, SE 1.06). RNFL and GCIPL produced floors at -17.8 (SE 0.927) and -23.6 dB (SE 1.14). The highest number of steps to measurement floor belonged to RNFL (7.20) and GCIPL (7.33), followed by pPDZ (4.25), mVAD (3.87), and mVSD (3.81), with 2.5 or fewer steps for pVAD, mPDZ, and mVDZ. CONCLUSIONS: pPDZ, mVAD, and mVSD had approximately 4 steps within their dynamic ranges, without true measurement floors, and thus may be useful in evaluating advanced glaucomatous progression. Improving OCTA test-retest repeatability could augment number of steps for OCTA metrics, increasing their clinical utility.


Assuntos
Glaucoma , Fibras Nervosas , Angiografia , Estudos Transversais , Glaucoma/diagnóstico , Humanos , Pressão Intraocular , Células Ganglionares da Retina , Vasos Retinianos/diagnóstico por imagem , Tomografia de Coerência Óptica
18.
Br J Ophthalmol ; 105(11): 1534-1541, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-32917629

RESUMO

OBJECTIVE: To compare intrasession repeatability versus intersession reproducibility of the peripapillary vessel parameters using optical microangiography-based optical coherence tomography angiography (OCTA) in non-glaucomatous and glaucomatous eyes. METHODS: In an observational, longitudinal study, peripapillary OCTA scans were collected to evaluate intrasession repeatability and intersession reproducibility using within-eye coefficient of variation (CVW) and intraclass correlation coefficient (ICC). Images were quantified using a custom research-oriented quantification software calculating vessel area density (VAD) and flux and a commercially developed, clinic-oriented quantification software (Cirrus 11.0, Carl Zeiss Meditec) calculating perfusion density (PD) and flux index (FI). Effect of signal strength on the reliability of OCTA parameters was also evaluated. RESULTS: Among 120 non-glaucomatous eyes, intrasession CVW were 4.2% for VAD, 5.3% for flux, 1.5% for PD and 2.0% for FI. The intersession CVW were 6.5% for VAD, 8.0% for flux, 2.0% for PD and 3.2% for FI. The intrasession ICC ranged from 0.928 to 0.945, and intersession ICC ranged from 0.811 to 0.866. From 118 glaucomatous eyes, intrasession CVW was 9.0% for VAD, 10.3% for flux, 1.7% for PD and 2.3% for FI. The intersession CVW was 12.1% for VAD, 14.2% for flux, 2.3% for PD and 3.5% for FI. The intrasession ICC ranged from 0.904 to 0.972, and intersession ICC ranged from 0.855 to 0.955. Signal strength was significantly positively associated with OCTA vessel parameters (p<0.0001) for both groups. CONCLUSION: Peripapillary OCTA vessel parameters had greater intrasession repeatability compared to intersession reproducibility in both non-glaucomatous and glaucomatous eyes. The built-in commercially developed quantification software demonstrated greater agreement than the custom research-oriented quantification software.


Assuntos
Glaucoma , Angiografia , Glaucoma/diagnóstico , Humanos , Estudos Longitudinais , Disco Óptico , Reprodutibilidade dos Testes , Tomografia de Coerência Óptica
19.
Ophthalmology ; 128(7): 1005-1015, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33217471

RESUMO

PURPOSE: To compare peripapillary retinal nerve fiber layer (RNFL) thickness among healthy adults by race and ethnicity and to identify determinants of RNFL thickness. DESIGN: Population-based cross-sectional study. PARTICIPANTS: Data from 6133 individuals (11 585 eyes) from 3 population-based studies in Los Angeles County, California, 50 years of age or older and of self-described African, Chinese, or Latin American ancestry. METHODS: We measured RNFL thickness and optic nerve head parameters using the Cirrus HD-OCT 4000. Multivariate linear mixed regression was used to evaluate factors associated with RNFL thickness among participants without ocular diseases. MAIN OUTCOME MEASURES: Determinants and modifiers of RNFL thickness. RESULTS: The mean age of the participants was 60.1 years (standard deviation, 7.4 years). Black Americans showed the lowest RNFL thickness and smallest cup-to-disc ratio (CDR), and Chinese Americans showed the largest CDR and disc area after adjusting for age and gender (all P < 0.05). Per each 10-year older age group, the average RNFL thickness was 2.5 µm (95% confidence interval [CI], 1.8-3.1 µm), 2.8 µm (95% CI, 2.3-3.3 µm), and 3.5 µm (95% CI, 2.9-4.1 µm) thinner for Black, Chinese, and Latino Americans, respectively (age trend P < 0.05 and interaction P = 0.041). Black Americans compared with Chinese Americans, older age, male gender, hypertension, diabetes, greater axial length (AL), bigger disc area, and lower scan signal strength were associated with thinner average RNFL. Race, age, AL, disc area, and scan signal strength consistently were associated with RNFL thickness in all quadrants, whereas gender, hypertension, and diabetes were associated with RNFL thickness in select quadrants. Age and race explained the greatest proportion of variance of RNFL thickness. CONCLUSIONS: Clinically important differences in RNFL thickness are present in healthy adults 50 years of age or older from different racial and ethnic groups of the same age, with the thinnest measures observed in Black Americans. This difference remains after accounting for disc size and AL. Furthermore, age-related RNFL thinning differs by race and ethnicity. Longitudinal studies are needed to verify our findings and to assess the influence of race and ethnicity in the clinical application of RNFL thickness.


Assuntos
Etnicidade , Vigilância da População/métodos , Células Ganglionares da Retina/citologia , Tomografia de Coerência Óptica/métodos , Negro ou Afro-Americano , Idoso , Idoso de 80 Anos ou mais , Asiático , Estudos Transversais , Feminino , Seguimentos , Hispânico ou Latino , Humanos , Los Angeles/epidemiologia , Masculino , Pessoa de Meia-Idade , Fibras Nervosas , Valores de Referência , Estudos Retrospectivos , Fatores de Tempo
20.
Ophthalmol Glaucoma ; 3(3): e3-e5, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32672625
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...